SKU: 99555
Shop with confidence! This product has been fully inspected to avoid any buyer surprises. Read our in-depth product listing below.
Your purchase will NOT include: - other accessories not shown or listed here.Prior to testing this autoclave, it was disassembled down to the bare chassis, cleaned, rebuilt and refurbished. Removed and rebuilt the Door Latch assembly. Cleaned and flushed the Reservoir Tank and installed a new Condenser Coil. Installed a new Fill Valve Solenoid, Vent Valve Solenoid and Air Valve Solenoid. Installed a new Dam Gasket , Heating Element, and Mesh Water Filters. Cleaned the Sterilizing Trays and Rack. Then proceeded to test the sterilizer by connecting it to a 120 volt power source, adding distilled water and running the autoclave through all it's preset sterilizing and drying cycles. To verify that this autoclave is achieving it's required maximum sterilizing temperature, it was temperature tested using a Max Register Thermometer, and found to reach 273 F for an entire cycle.
Technician Testing Notes
Prior to testing this autoclave, it was disassembled down to the bare chassis, cleaned, rebuilt and refurbished. Removed and rebuilt the Door Latch assembly. Cleaned and flushed the Reservoir Tank and installed a new Condenser Coil. Installed a new Fill Valve Solenoid, Vent Valve Solenoid and Air Valve Solenoid. Installed a new Dam Gasket , Heating Element, and Mesh Water Filters. Cleaned the Sterilizing Trays and Rack. Then proceeded to test the sterilizer by connecting it to a 120 volt power source, adding distilled water and running the autoclave through all it's preset sterilizing and drying cycles. To verify that this autoclave is achieving it's required maximum sterilizing temperature, it was temperature tested using a Max Register Thermometer, and found to reach 273 F for an entire cycle.
Prior to testing this autoclave, it was disassembled down to the bare chassis, cleaned, rebuilt and refurbished. Removed and rebuilt the Door Latch assembly. Cleaned and flushed the Reservoir Tank and installed a new Condenser Coil. Installed a new Fill Valve Solenoid, Vent Valve Solenoid and Air Valve Solenoid. Installed a new Dam Gasket , Heating Element, and Mesh Water Filters. Cleaned the Sterilizing Trays and Rack. Then proceeded to test the sterilizer by connecting it to a 120 volt power source, adding distilled water and running the autoclave through all it's preset sterilizing and drying cycles. To verify that this autoclave is achieving it's required maximum sterilizing temperature, it was temperature tested using a Max Register Thermometer, and found to reach 273 F for an entire cycle.
Product Condition
- Manufacturer: Midmark
- Model: M9
- Serial Number: V31151
- Power Requirements: 115V
- Year: 2004
- Sterilizer Type: Autoclave (Steam Sterilizer)
- Timer Function: features a basic timer with preset timing options
- Controls: digital control display
- Chamber Depth: 14"
- Chamber Diameter: 9"
- Number of Trays: 4 trays
- Cycle Count: 7915
30 Day Return Guarantee
Your satisfaction is important to us: Have your equipment installed by a factory-trained technician or Atlas-approved vendor to qualify for our return policy.See our Terms and Conditions of Sale for details.