SKU: 98527
Shop with confidence! This product has been fully inspected to avoid any buyer surprises. Read our in-depth product listing below.
Your purchase will NOT include: This product is pre-owned and may not include the same accessories as a new, unused unit. - other accessories not shown or listed here.Visually inspected the unit for any damaged or missing parts and accessories. Cleaned the Reservoir Tank and installed a new Condenser Coil. Installed a new Fill and Vent Valve Solenoid and Steam Bellows. Installed a new Temperature Sensor, Digital Display and Display. Installed a new Door Panel, Door Gasket, Dam Gasket and Mesh Water Filter. Cleaned the sterilizing chambe, sterilizing trays and rack. To test this autoclave, it was connected to a 120 volt power source, distilled water was added and then the control board was calibrated. The calibration proved to be successful, I then began running cycles on the unit. Ran this autoclave tru all it's preset sterilizing and drying cycles several times. To verify that it is achieving it's requiredmaximum sterilizing temperature during a cycle, it was tested using a Max Register Thermometer, and found to exceed 273 F for an entire cycle.
Technician Testing Notes
Visually inspected the unit for any damaged or missing parts and accessories. Cleaned the Reservoir Tank and installed a new Condenser Coil. Installed a new Fill and Vent Valve Solenoid and Steam Bellows. Installed a new Temperature Sensor, Digital Display and Display. Installed a new Door Panel, Door Gasket, Dam Gasket and Mesh Water Filter. Cleaned the sterilizing chambe, sterilizing trays and rack. To test this autoclave, it was connected to a 120 volt power source, distilled water was added and then the control board was calibrated. The calibration proved to be successful, I then began running cycles on the unit. Ran this autoclave tru all it's preset sterilizing and drying cycles several times. To verify that it is achieving it's requiredmaximum sterilizing temperature during a cycle, it was tested using a Max Register Thermometer, and found to exceed 273 F for an entire cycle.
Visually inspected the unit for any damaged or missing parts and accessories. Cleaned the Reservoir Tank and installed a new Condenser Coil. Installed a new Fill and Vent Valve Solenoid and Steam Bellows. Installed a new Temperature Sensor, Digital Display and Display. Installed a new Door Panel, Door Gasket, Dam Gasket and Mesh Water Filter. Cleaned the sterilizing chambe, sterilizing trays and rack. To test this autoclave, it was connected to a 120 volt power source, distilled water was added and then the control board was calibrated. The calibration proved to be successful, I then began running cycles on the unit. Ran this autoclave tru all it's preset sterilizing and drying cycles several times. To verify that it is achieving it's requiredmaximum sterilizing temperature during a cycle, it was tested using a Max Register Thermometer, and found to exceed 273 F for an entire cycle.
Product Condition
- Manufacturer: Midmark
- Model: M9
- Serial Number: CZ008494
- Power Requirements: 120V
- Year: 1999
- Sterilizer Type: steam chamber
- Timer Function: features a timer with a variety of cycle options
- Controls: digital control display
- Chamber Depth: 15"
- Chamber Diameter: 9"
- Number of Trays: 4 trays
- Cycle Count: Cycle count is not available on this autoclave.
Item Includes:
1 - Midmark M9 Autoclave 4 - Sterilizing Trays w/ Rack 1 - Attached Power Cord
Item Excludes:
This product is pre-owned and may not include the same accessories as a new, unused unit.
1 - Midmark M9 Autoclave 4 - Sterilizing Trays w/ Rack 1 - Attached Power Cord
Item Excludes:
This product is pre-owned and may not include the same accessories as a new, unused unit.
Shipping calculated at checkout.
30 Day Return Guarantee
Your satisfaction is important to us: Have your equipment installed by a factory-trained technician or Atlas-approved vendor to qualify for our return policy.See our Terms and Conditions of Sale for details.