Better Selection

on used dental equipment

SciCan STATIM 5000 Dental Autoclave Cassette Medical Steam Sterilizer
SciCan STATIM 5000 Dental Autoclave Cassette Medical Steam Sterilizer
SciCan STATIM 5000 Dental Autoclave Cassette Medical Steam Sterilizer
SciCan STATIM 5000 Dental Autoclave Cassette Medical Steam Sterilizer
SciCan STATIM 5000 Dental Autoclave Cassette Medical Steam Sterilizer
SciCan STATIM 5000 Dental Autoclave Cassette Medical Steam Sterilizer
SciCan STATIM 5000 Dental Autoclave Cassette Medical Steam Sterilizer
SciCan STATIM 5000 Dental Autoclave Cassette Medical Steam Sterilizer
SciCan STATIM 5000 Dental Autoclave Cassette Medical Steam Sterilizer
  • Load image into Gallery viewer, SciCan STATIM 5000 Dental Autoclave Cassette Medical Steam Sterilizer
  • Load image into Gallery viewer, SciCan STATIM 5000 Dental Autoclave Cassette Medical Steam Sterilizer
  • Load image into Gallery viewer, SciCan STATIM 5000 Dental Autoclave Cassette Medical Steam Sterilizer
  • Load image into Gallery viewer, SciCan STATIM 5000 Dental Autoclave Cassette Medical Steam Sterilizer
  • Load image into Gallery viewer, SciCan STATIM 5000 Dental Autoclave Cassette Medical Steam Sterilizer
  • Load image into Gallery viewer, SciCan STATIM 5000 Dental Autoclave Cassette Medical Steam Sterilizer
  • Load image into Gallery viewer, SciCan STATIM 5000 Dental Autoclave Cassette Medical Steam Sterilizer
  • Load image into Gallery viewer, SciCan STATIM 5000 Dental Autoclave Cassette Medical Steam Sterilizer
  • Load image into Gallery viewer, SciCan STATIM 5000 Dental Autoclave Cassette Medical Steam Sterilizer

SciCan STATIM 5000 Dental Autoclave Cassette Medical Steam Sterilizer

Regular price
$3,000.00
Sale price
$3,000.00
Regular price
Sold out
Unit price
per 

Shop with confidence! This product has been fully inspected to avoid any buyer surprises. Read our in-depth product listing below.

Your purchase will NOT include: This product is pre-owned and may not include the same accessories as a new, unused unit. - other accessories not shown or listed here.
Prior to testing this autoclave, it was inspected to verify it's functionality and cosmetic condition. Then it was completely disassembled down to it's bare chassis, cleaned and rebuilt using it's existing components and installing new components. The Reservoir Tank was cleaned inside and out, and a new Reservoir Cap, Reservoir Filter and Water Pump Filter and Drain Kit upgrade were installed. For Preventive Maintenance Purposes, A new Water Pump, Safety Valve, Boiler Check Valve and Biological Filter were installed. Disassembled the Air Valve Solenoid, cleaned and installed a new Air Valve Plunger. Installed a new Probe Bracket Assembly and chamber Microswitch. Disassembled the Sterilizing Cassette, cleaned, rebuilt and installed a new Cassette Seal. To test this sterilizer, it was properly levelled to ensure cassette drying. Then it was connected to a 120 volt power source, a donor condenser waste bottle was attached and distilled water was added. Then the autoclave was calibrated to verify it's making it's required sterilizing temperature, and was then tested with a Max Register Thermometer and found to exceed 273 F for an entire cycle. To verify that this autoclave is functioning correctly, it was run through all it's preset sterilizing and drying cycles several times. And no issues came up during it's testing.
Technician Testing Notes
Prior to testing this autoclave, it was inspected to verify it's functionality and cosmetic condition. Then it was completely disassembled down to it's bare chassis, cleaned and rebuilt using it's existing components and installing new components. The Reservoir Tank was cleaned inside and out, and a new Reservoir Cap, Reservoir Filter and Water Pump Filter and Drain Kit upgrade were installed. For Preventive Maintenance Purposes, A new Water Pump, Safety Valve, Boiler Check Valve and Biological Filter were installed. Disassembled the Air Valve Solenoid, cleaned and installed a new Air Valve Plunger. Installed a new Probe Bracket Assembly and chamber Microswitch. Disassembled the Sterilizing Cassette, cleaned, rebuilt and installed a new Cassette Seal. To test this sterilizer, it was properly levelled to ensure cassette drying. Then it was connected to a 120 volt power source, a donor condenser waste bottle was attached and distilled water was added. Then the autoclave was calibrated to verify it's making it's required sterilizing temperature, and was then tested with a Max Register Thermometer and found to exceed 273 F for an entire cycle. To verify that this autoclave is functioning correctly, it was run through all it's preset sterilizing and drying cycles several times. And no issues came up during it's testing.
Product Condition
  • Manufacturer: SciCan
  • Model: STATIM 5000
  • Serial Number: 5103GA0145
  • Power Requirements: 110V
  • Year: 2006
  • Sterilizer Type: steam cassette
  • Timer Function: features a timer with a variety of cycle options
  • Controls: digital control display
  • Chamber Depth: N/A
  • Chamber Diameter: N/A
  • Number of Trays: 1 tray
  • Cycle Count: 10 cycles on a reset control board.
Item Includes:
1 - SciCan STATIM 5000 Cassette Autoclave 1 - Sterilizing Cassette w/ Rack and new Cassette Seal installed. 1 - Condenser Waste Bottle 1 - Power Cord

Item Excludes:
This product is pre-owned and may not include the same accessories as a new, unused unit.
Shipping calculated at checkout.

30 Day Return Guarantee

Your satisfaction is important to us: Have your equipment installed by a factory-trained technician or Atlas-approved vendor to qualify for our return policy.See our Terms and Conditions of Sale for details.