SKU: 103257
Shop with confidence! This product has been fully inspected to avoid any buyer surprises. Read our in-depth product listing below.
Your purchase will NOT include: manufacturer warranty, or any other accessories not shown or listed here.Attached unit to required 120V power source, as well as attaching vacuum pump to designated location. Once attachments were in place, powered unit on. Units digital display is free of damage and is fully legible. Tested all keypad functions to ensure respond to touch. They all do. Press opens and closes as intended. Muffle and insulation of unit are free of damage and in good condition. Ran preset program on unit to ensure unit reaches and maintains temp, unit builds temp as well as maintains. This programat CS2 does not have adequate vacuum build up. ERROR 33 which is an indication of Necessary vacuum (xxxmbar) is not reached within 1 min. As well as ERROR 802 which states The vacuum does not increase (self-test). Both errors refer to the feature/function of vacuum pump. Checked furnace seal, fuses, vacuum pump connection as well as hose. All are in good condition and within required range for function. Due to unit not being able to complete a full program/self test and inability to use vacuum pump the way it's intended unit is AS-IS.
Technician Testing Notes
Attached unit to required 120V power source, as well as attaching vacuum pump to designated location. Once attachments were in place, powered unit on. Units digital display is free of damage and is fully legible. Tested all keypad functions to ensure respond to touch. They all do. Press opens and closes as intended. Muffle and insulation of unit are free of damage and in good condition. Ran preset program on unit to ensure unit reaches and maintains temp, unit builds temp as well as maintains. This programat CS2 does not have adequate vacuum build up. ERROR 33 which is an indication of Necessary vacuum (xxxmbar) is not reached within 1 min. As well as ERROR 802 which states The vacuum does not increase (self-test). Both errors refer to the feature/function of vacuum pump. Checked furnace seal, fuses, vacuum pump connection as well as hose. All are in good condition and within required range for function. Due to unit not being able to complete a full program/self test and inability to use vacuum pump the way it's intended unit is AS-IS.
Attached unit to required 120V power source, as well as attaching vacuum pump to designated location. Once attachments were in place, powered unit on. Units digital display is free of damage and is fully legible. Tested all keypad functions to ensure respond to touch. They all do. Press opens and closes as intended. Muffle and insulation of unit are free of damage and in good condition. Ran preset program on unit to ensure unit reaches and maintains temp, unit builds temp as well as maintains. This programat CS2 does not have adequate vacuum build up. ERROR 33 which is an indication of Necessary vacuum (xxxmbar) is not reached within 1 min. As well as ERROR 802 which states The vacuum does not increase (self-test). Both errors refer to the feature/function of vacuum pump. Checked furnace seal, fuses, vacuum pump connection as well as hose. All are in good condition and within required range for function. Due to unit not being able to complete a full program/self test and inability to use vacuum pump the way it's intended unit is AS-IS.
Product Condition
- Manufacturer: Ivoclar Vivadent
- Model: Programat CS
- Serial Number: 4041002765
- Power Requirements: 120V
- Year: 2015
Item Includes:
Cooling plate Firing trays Power cable
Item Excludes:
VACUUM PUMP
Cooling plate Firing trays Power cable
Item Excludes:
VACUUM PUMP
Shipping calculated at checkout.
30 Day Return Guarantee
Your satisfaction is important to us: Have your equipment installed by a factory-trained technician or Atlas-approved vendor to qualify for our return policy.See our Terms and Conditions of Sale for details.